Welcome to the official website of Jiangsu Muse Environmental Technology Co., Ltd.!

National Advisory Hotline:138-1800-2333
How to replace the filter bag of the pulse bag filter
Current position: HOME > NEWS > Industry Information > How to replace the filter bag of the pulse bag filter

How to replace the filter bag of the pulse bag filter

Classification:MUSE Release date:2020-11-14 14:18 Views

  How to replace the filter bag of the pulse bag filter

  When most of the filter bags of the pulse bag filter are damaged, all should be replaced. It is better to replace the filter bags when the dust collector stops working. At this time, the ash cleaning controller should be turned off. On-site operators must wear dust masks for protection, wear goggles and hoods, and ensure that they can remove the dust bag afterwards. Open the inlet door on the top of the bag filter to disassemble the filter bag. When disassembling, first take out the bag cage, then pinch the spring ring on the top of the bag into a concave shape, pull up the dust bag before installing the new bag , The dust on the hole of the flower plate should be cleaned. When installing a new filter bag, hold the open end of the dust filter bag with your hand while keeping the rest of the dust filter bag folded, and push the folded dust bag part into the sleeve to penetrate the flower plate. After the folded part of the dust removal cloth bag is opened under the flower board, release the top of the dust removal cloth bag, and let the groove-shaped cushion spring ring rest on the sleeve of the flower board. Let the weight of the dust filter bag slowly fix the position, and let the metal ring pull out the sleeve from the top of the dust bag. Install the sleeve in the hole of the flower plate.

  How to replace the filter bag of the pulse bag filter

  Hold the groove-shaped cushion spring ring firmly with both hands, and press the spring ring inward with both hands to form a “C” shape. While keeping the spring ring in a “C” shape, place the raised side of the grooved spring ring to the edge of the nearest flower plate hole. One hand holds one side of the installed raised “C” shaped spring ring, and the other hand fixes the raised “C” shape on the edge of the flower plate. Fix the position of one side of the raised “C” spring loop with one hand, and slowly stretch the other side of the spring loop with the other hand. Insert the groove of the spring ring into the hole of the flower plate. If you can’t hear the “pop” sound when the spring ring is fully extended, push the spring ring toward the inner edge of the plate with the female finger of one hand, so that the groove of the spring ring fits into the inner edge of the plate hole . After installing the new filter bag of the bag filter, insert it into the bag cage. After the filter bag and the bag cage are installed, install the blowing pipe and close the empty door.

【Related news】

Expressway